iPCS Isolated Power Control Station

Manufacturer:

Model Number: IPCS750-TNET

Type: UPS/Backup Battery

WHAT IT DOES

  • Emergency power during a power outage
  • TBF™ Electronic Power Conditioning
  • Receptacles controlled from remote location
  • Auto reboot of non-responsive connected equipment

PROTECTION AGAINST…

  • Blackouts – With battery backup
  • Spikes and surges – With TBF™ Technology
  • Under or over voltage fluctuations – With voltage regulation
  • Lightning – With surge protection

BENEFITS

  • Increase uptime
  • Save money on power related service calls
  • Improve business productivity
  • Protected equipment lasts longer

IPCS750-TNET Features

  • Independent Controllable Outlets: Independent remote switchable outlets to turn on/off/reboot connected devices to prevent data loss or corruption. All from a remote and central location.
  • Outlets can be turned on in sequence
  • Battery and TBF™ protected outlets
  • Full Control via LCD display: Easy-to-read LCD display provides information about power conditions. The LCD display will show how much time is left before the UPS will turn back on or shut down. Unit can be controlled via LCD display and via software. Fully monitored and controlled over Network/Internet.
  • Realtime Network Monitoring and Notifications: Remote management and configuration via Web Browser, NMS. Event logging to trace the operation’s history. Graphic data logging to analyze power conditions. Event notifications via Email, SNMP traps. Ability to set up alerts when the battery needs replacement. Supports Environmental Sensor (optional). Advanced Enterprise power management software.
  • Light and Versatile: Unit is light enough to be installed in Under Counter Configuration.
  • Cord Organization: Keep your racks organized and cables plugged in with the organizing tray. It prevents cables from being disconnected and features color-coded outlets.
  • Intelligent detection and Automatic Restart of Locked-up Equipment: The iPCS can detect and monitor connected equipment over the network and automatically restart unresponsive equipment by turning that particular receptacle off and on.
  • Catastrophic Event Protection: If a catastrophic event happens, the only part affected will be the On-Cord Electronic Power Conditioner, thus saving the connected equipment and the rest of the unit.
  • Features:
    • Electronic power conditioner TBF™
    • Line interactive / pure sine wave output design
    • 8 independent remote switchable outlets to on/off/reboot connected devices through the network interface. All outlets are UPS-TBF protected
    • Fully informative LCD display to show power loads and UPS stats
    • Automatic voltage regulator (AVR and battery backup in one unit)
    • Power management software with network monitoring capability with diagnostic and battery check
    • Short circuit and overload protection
    • Tel/Network (RJ11/RJ45) protection
    • HID USB and Smart RS232 communications port
    • User replaceable UPS battery
    • SNMP network management capability
    • EPO (Emergency Power Off) capable
    • Two year warranty – Optional extended warranty

Part Number(s):

  • IPCS750-TNET
  • IPCS1000-TNET

Accessories:

View the full extent of our products

Download our free product catalog today!

Detailed Specifications

  • Model

    IPCS750-TNET

  • Capacity

    750VA / 600W

  • Rated Power Factor

    0.8

  • Input

    Input Voltage Range: 82-148Vac, Frequency Range: 60Hz ± 3Hz

  • Output

    On Battery Output Voltage: Sine Wave at 100-127Vac ±10%, On Battery Output Frequency: 60Hz ±1Hz, Overload Protection: Yes

  • Protection

    Transient Let-Through Voltage: <0.5V Common Mode (N-G) / <10V Normal Mode (L-N). Smart Power Systems is the only one that publishes N-G Pass Through Voltage

  • AVR Function

    Boost Function: Yes, Buck Function: Yes

  • Physical

    Receptacles: 8-NEMA 5-15R (Battery & power conditioning) 8 x remote switchable outlet banks, Maximum Dimensions (HxDxW): 3.5 x 16.9 x 22, Weight: 25.20 Lbs / 11.44 Kg

  • Configuration

    Form Factor: Rack-mount, Tower and Under Counter Configuration

  • Battery

    Sealed Maintenance-Free Lead Acid Battery: 12Vdc, Typical Recharge Time: Rack-mount, Tower and Under Counter Configuration, Estimated Battery Mode Runtime: 6 min 42 sec (at 50% load)